Miami-Dade County, Florida,
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| "Miami-Dade
County Product Control Approved"(Click to open) Miami-Dade Web Site Search Instructions (Click to open) |
|||
| Miami-Dade Building Compliance Website | |||
| Notice of Acceptance | |||
| Bahama and Bahama over Colonial Shutters | |||
| Miami-Dade County, Florida, NOA: 09-0122.07, Expiration Date 11/28/2012 (Click NOA to open file) |
|||
| Miami-Dade County, Florida, website search for approved Bahama Shutter Company’s | |||
| 04/05/11 Miami-Dade County, Florida Approved Bahama NOA’s | |||
| Colonial and Bahama over Colonial Shutters | |||
| Miami-Dade County, Florida, NOA: 09-0122.08, Expiration Date 11/28/2012 (Click NOA to open file) |
|||
| Miami-Dade County, Florida, website search for approved Colonial Shutter Company’s | |||
| 04/05/11 Miami-Dade County, Florida Approved Colonial NOA’s | |||
| Design Pressures | |||||||||||
| Bahama Hurricane Shutter Systems | |||||||||||
|
|||||||||||
| Colonial Hurricane Shutter Systems | |||||||||||
|
|||||||||||
| Bahama over Colonial Hurricane Shutter Systems | |||||||||||
|
|||||||||||
| Lab Certifications | |||||||||||
Miami-Dade County (05-1014.01), Florida Building Code (TST1527), IAS-ES (TL-244), AAMA, WDMA, Keystone Certifications, & Texas Department of Insurance |
|||||||||||
| Test Criteria: | |||||||||||
Uniform Static Load Test, Florida Building Code TAS 202 and ASTM E 330 |
|||||||||||
Large Missile Impact, Florida Building Code TAS 201 and ASTM E1886/1996 Level D |
|||||||||||
Cycle Load Test, Florida Building Code TAS 203 and ASTM E1886/1996 |
|||||||||||
| Design Pressure Analysis of Vented Louvered Shutter (Click to open) | |||||||||||
FBC Section R4410.4 High-Velocity Hurricane Zone Storm shutter / External Protective Devices (Click to open) |
|||||||||||
2007 Florida Building Code: Test protocols (First Print) including 2009 Supplements, Decorative Shutters, Cyclic Test TAS 203 |
|||||||||||
| Decorative Shutters Certification and Engineering (Click to open) | |||||||||||
| Decorative Shutter FBC-09 Drawings (Click to open) | |||||||||||
| Fastener Schedules | |||||||||||
| 110 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 115 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 120 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 125 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 130 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 135 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 140 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 145 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 150 mph Wind Velocity, Exposure B & C (Click to open) | |||||||||||
| 155 & 179.6 mph Wind Velocity , Exposure C (Click to open) | |||||||||||
| 165.6 mph Wind Velocity , Exposure D (Click to open) | |||||||||||
| Design Pressures | |||||||||||
| Decorative Bahama Shutter Systems | |||||||||||
|
|||||||||||
| Decorative Colonial Shutter Systems | |||||||||||
|
|||||||||||
| Decorative Bahama over Colonial Shutter Systems | |||||||||||
|
|||||||||||
| Test Criteria: | |||||||||||
Tested and Certified - Florida Building Code TAS 203-94 (Cycle Wind Pressure Loading) ASTM E1233-06 (Cycle Air Pressure Differential) |
|||||||||||
| HVHZ & Non-HVHZ Test Procedures, Decorative Shutters 08/20/09, Miami-Dade Compared to FBC: Uniform Static Test TAS 202 (FBC HVHZ - Miami-Dade) & ASTM E330 (FBC Non-HVHZ) (Click to open) | |||||||||||
Our Decorative Shutters are also tested for Cyclic Test Procedures (not Required by current FBC) TAS 203 (FBC HVHZ – Miami-Dade) & ASTM E#1886/E1996 (FBC Non-HVHZ) |
|||||||||||
Our Decorative Shutters ARE NOT Tested for Impact Test Procedures: TAS 201 (FBC HVHZ – Miami-Dade) & ASTM E1886/E1996 (FBC Non-HVHZ) Impact Tests |
|||||||||||
| Design Pressure Analysis of Vented Louvered Shutter (Click to open) | |||||||||||